TRIPLE B GARAGE DOORS AND GATES

Your Local Garage Door and Gate Experts!

HOA Gate Safety Guide: UL 325 and ASTM F2200 for Community Gates

Based in Mesa, Serving the Entire Phoenix Metro Area

Updated October 2026.

An automatic community gate moves several hundred pounds of steel or aluminum on a timer, many times a day, with residents, children, delivery drivers and pets around it. Two national standards set out what keeps that gate from trapping or striking someone: UL 325 for the operator, and ASTM F2200 for the gate itself. This guide is for HOA boards and community managers who want to know what those standards ask for, what to check, and what to ask a gate company.

Triple B builds and services steel and aluminum gates and gate operators across the Valley. Every repair is quoted and confirmed before we start.

On this page

The Two Standards

UL 325 covers the gate operator, the motor and controls that move the gate. It sets the operator classes, the entrapment protection the operator must have, and the instructions and warning signs that come with it. Gate operator provisions were added to UL 325 in the early 1990s, according to DASMA Technical Data Sheet 353. UL 325 is in its 7th edition, last revised in September 2025.

ASTM F2200, the Standard Specification for Automated Vehicular Gate Construction, covers the gate itself: openings, gaps, rollers, stops and what happens if the gate comes off its hardware. UL 325 points to ASTM F2200 for gate construction, so a compliant operator on a non-compliant gate is still a non-compliant system.

Neither standard is a federal law. They are written into the building and fire codes that Arizona cities adopt, and inspectors check new installations against them (DASMA Technical Data Sheet 356).

Which Class Your Community Gate Falls Under

UL 325 sorts gate operators into four classes. The definitions below are quoted in DASMA Technical Data Sheet 353.

ClassIntended use
Class IGarages or parking areas for one to four single family homes
Class IICommercial or general access, such as multi-family housing of five or more units, hotels, garages, retail and other buildings serving the general public
Class IIIIndustrial locations not open to the general public, such as a factory or loading dock
Class IVGuarded restricted locations, such as an airport security area, with security personnel on site

A community entrance gate that serves more than four homes is outside Class I, so check that the operator is listed for Class II. The operator must be permanently marked with every class it is listed for, so the label on the operator tells you whether it was built for your gate.

UL 325 also limits Class I and Class II slide gate operators to 1 foot per second when pulling 75 pounds or more.

Entrapment Protection on the Operator

UL 325 defines entrapment as “the condition when an object is caught or held in a position that increases the risk of injury.” The operator has to protect every place along the gate’s path where that can happen.

The core rules, from UL 325 section 32 as reprinted in DASMA Technical Data Sheet 353:

  • Two independent means of protection for each entrapment zone, in each direction of travel. A swing gate with no entrapment zone in one direction needs one means in that direction and two in the other.
  • Two different types. The same type of device cannot count as both means.
  • The operator will not run until the minimum number of devices is installed and enabled.
  • Reversal within 2 seconds after sensing an obstruction, traveling at least 2 inches.

The types of protection UL 325 recognizes:

TypeWhat it is
Type AInherent sensing built into the operator
Type B1Non-contact sensor, such as a photo eye
Type B2Contact sensor, such as a sensing edge on the gate
Type CInherent force limiting, clutch or pressure relief (swing gates and barrier arms only)
Type DA control that must be held down to keep the gate moving

Monitored sensors since 2016. Since January 12, 2016, photo eyes and sensing edges must be monitored. An operator made in 2016 or after checks for its sensors on every cycle and will not run normally if one is missing, unplugged or faulty (DASMA, Door + Access Systems, Spring 2016). The standard forbids bypassing that check with jumpers, switches or extra wiring. The same change ended the use of an audio alarm (Type E) as entrapment protection.

Each sensor must also be listed to UL 325 and approved by the operator’s manufacturer. A photo eye from one brand is not automatically accepted by another brand’s operator.

What ASTM F2200 Requires of the Gate

The figures below come from the gate construction section of the DoorKing Model 6400 installation manual (2013) and DASMA Technical Data Sheet 356, both of which quote ASTM F2200 and the UL 325 instructions. The full standard is sold by ASTM. The current edition, F2200-24, added bifold gates and requires the system to comply with UL 325 as well.

Slide gates

  • All openings from the bottom of the gate to at least 6 feet above the ground are guarded or screened so a 2 1/4 inch sphere cannot pass through. This covers the whole gate and the section of fence the gate covers when it is open. A gate under 6 feet tall is screened to the top.
  • Exposed rollers are guarded.
  • Positive stops keep the gate from traveling past its open and closed limits.
  • The gate cannot fall over if it comes loose from its supporting hardware.

Swing gates

  • The gate is installed with enough clearance from walls, columns and other fixed objects that it does not create an entrapment area.
  • Swing gates should not open into public access areas, such as a sidewalk.
  • Swing gates do not need the 2 1/4 inch screening that slide gates need.

All gates

  • Bottom edges are smooth, with no vertical protrusions over 1/2 inch.
  • Exposed pinch points are eliminated or guarded.

Controls, Signs and Pedestrian Gates

Keypads and card readers. UL 325 requires user controls to be at least 6 feet from any moving part of the gate, placed so no one can reach over, under, around or through the gate to use them. Some manufacturers ask for more; the DoorKing manual above calls for 10 feet. Follow whichever is greater.

Reset button. The control used to reset the operator after it stops on a second obstruction must be in sight of the gate, so whoever resets it can see what caused the stop.

Warning signs. At least two warning signs, one on each side of the gate, where they are easy to see.

Pedestrian gate. A vehicle gate operator is for vehicles only. Where people walk through the area, UL 325 requires a separate pedestrian gate, placed so people do not come into contact with the vehicle gate at any point in its travel.

Vehicle detection. Loops, photo eyes or equivalent devices keep the gate from closing on a car. These protect vehicles; they are separate from the entrapment protection that protects people.

Fire Department Access

The International Fire Code, which Valley cities adopt with their own amendments, covers gates across fire access roads. In the 2018 edition, section 503.6, the gate must be approved by the fire code official and must have an approved means of emergency operation, kept working at all times. Electric gate operators must be listed to UL 325, and automatic gates must meet ASTM F2200. Your city fire department sets the emergency opening method it accepts.

Most cities in Arizona require two different preemption devices so emergency vehicles can open the gate. Typically that is a keyed Knox key switch for the fire department, and a dual Tomar strobe detector for all other emergency vehicles.

Older Gates

UL 325 is not retroactive. An operator installed under an older edition does not have to be upgraded because the standard changed (DASMA Technical Data Sheet 356).

Two points from the same sheet are worth knowing:

  • Two means of entrapment protection in each zone have been required since 2000. DASMA recommends replacing any operator made before 2000, because it may have no way to connect entrapment protection devices.
  • Whether a newer operator can be upgraded depends on the product, and the manufacturer has to be consulted.

When an operator is replaced, the new one is a monitored operator, and the gate has to have its sensors in place before it will run. Plan for the sensors in the same job.

Codes like these are generally put in place to improve safety, and in many cases they genuinely do help keep us safe.

A Monthly Checklist for the Board

Operator manuals call for a monthly test. With the gate area clear of people and cars:

  1. Close the gate and block the photo eye beam. The gate should stop or reverse.
  2. Press the sensing edge while the gate is moving. The gate should reverse.
  3. Look for missing or faded warning signs on both sides.
  4. Check that keypads and card readers are still at least 6 feet from the gate.
  5. Look for screening that has come loose on a slide gate, and for missing roller guards.
  6. Check the pedestrian gate opens and closes on its own.
  7. Check that the manual release works and the instructions for it are on the operator.

If a device does not work, take the operator out of service and call your gate company. The manuals say the same thing: do not run a gate with a failed safety device.

How Triple B Helps

We service gate operators of all major brands, and we custom fabricate steel (wrought iron) and aluminum gates built to the exact dimensions of the opening. On request, we will check a community gate against UL 325 and ASTM F2200 and give you a written list for you to decide next steps.

An automated commercial gate service call is $195, and it includes lubrication, minor adjustments, and testing and troubleshooting. Repairs are quoted and confirmed before we start.

Not every older gate needs a new operator. Our technicians will assess the problem, and present you with a clear, honest quote along with our recommendation.

We have been serving Arizona since 2012. ROC 284792.

Frequently Asked Questions

Is UL 325 the law in Arizona?

UL 325 is not a federal law. It is referenced in the International Building Code and International Fire Code, which Arizona cities adopt, and inspectors check new gate installations against it.

No. UL 325 is not retroactive, so an operator installed under an older edition does not have to be upgraded. A replacement operator must meet the current edition.

Operators made since 2016 monitor their photo eyes and sensing edges and will not run normally until those devices are installed and working. The fix is to install the sensors, never to bypass them.

UL 325 requires at least 6 feet from any moving part of the gate, placed so no one can reach through the gate to use it. Some manufacturers require 10 feet.

Yes, wherever people walk through the area. UL 325 says a vehicle gate operator is for vehicles only and pedestrians must use a separate entrance.

An automated commercial gate service call is $195, including lubrication, minor adjustments, and testing and troubleshooting. Any repair is quoted and confirmed before we start.